Banner with low poly plexus design

Epoxy Paint

  • Epoxy resin has reactive Oxirane groups that can be reacted with amine groups of various types of hardeners such as Polyamide, Polyamines, Cycloaliphatic amines, Phenalkamines, Phenalkmaides, etc.
  • Upon reaction with amines, oxirane groups open up into the hydroxyl group which offers excellent adhesion to the surface. The cured epoxy paint provides excellent resistance to corrosion and various chemicals, lubricating oils and petrochemical solvents.
  • Performance can be optimized by the selection of correct hardeners.
  • GP offers unique performance properties for its range of epoxy paint in India due to its institutional control over the hardener, which is tailor-made to offer a customized solution.

Industries we cover

Specializing in Superior Coatings for Every Industrial Needs

machine tools

Special Machine Tools

motor pump

Pump, motors, valves

Agriculture Equipment

Agriculture Equipment

Power and Electrical

Power and Electrical

auto component

Auto Components and Refinishing

Projects and Process

Projects and Process

Infrastructure and Construction

Infrastructure & Construction

railway industry

Railways

Defense

Defense

floor

Floor and Concrete

© 2025 Udwipan Coatings. All Rights Reserved. Trusted Partner – Grand Polycoats Company Pvt. Ltd.

GP Envirocoat Pure Polyester Powder Coatings are thermosetting powders based on durable polyester resins. They are specifically designed for exterior environment, offering excellent UV resistance, good resistance to discoloration & outstanding outdoor durability.

GP Envirocoat Epoxy Polyester Powder Coatings are thermosetting powders based on epoxy & polyester resins. They have good mechanical properties, excellent over bake resistance, very good chemical & corrosion resistance and outstanding flow-levelling characteristics. They are ideally suited for indoor applications.

Polyurethane Powder Coatings are thermosetting powders based on durable polyester resins cross linked with IPDI hardner suited for applications where excellent flow is required and where UV & outdoor resistance is required.

“GP ENVIROCOAT 205 ZR is a powder coating primer containing Zinc which is designated to impart excellent corrosion protection. It consists of two-coat system with Zinc Rich primer followed by powder coating Topcoat. This product is ideal for usage in C-3 & C-4 corrosion Environment system as per ISO 12944.”

  • Two component Aliphatic Polyurethane based mastic coat
  • Solid by Volume 60%
  • Application by Brush, spray, HVLP or Airless gun
  • Recommended DFT 100 – 120 micron over well prepared surface like St 2, St 3 or blast cleaned

  • Two component Aliphatic Polyurethane based unicoat
  • Solid by Volume 40%
  • Application by spray, HVLP or Airless gun
  • Recommended DFT 40 – 60 micron over well prepared surface like St 2, St 3 or blast cleaned

  • Acrylic Aliphatic Polyurethane
  • Solid by Volume 40%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 40 micron over primer
  • Recommended for Project Process, Power Electrical, Machine Tools, auto component both Ferrous and Nonferrous

  • Saturated Polyester Aliphatic Polyurethane
  • Solid by Volume 50%
  • Application by Roller, Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 40 micron over primer
  • Recommended for Oil and Gas, Defense, Railways

  • Acrylic Aliphatic Polyurethane
  • Solid by Volume 57%
  • Application by Roller, Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 50 – 75 micron over primer

  • Acrylic Aliphatic Polyurethane
  • Solid by Volume 57%
  • Application by Roller, Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 50 – 75 micron over primer

  • Acrylic Aliphatic Polyurethane
  • Solid by Volume 48%
  • Application by Roller, Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 50 – 60 micron over primer

  • Aliphatic Polyurethane based topcoat
  • Solid by Volume 40%
  • Application bu Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 -40 micron over primer
  • Recommended as an Topcoat for general industrial application

  • Acrylic Aliphatic Polyurethane
  • Solid by Volume 40%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 40 micron over primer

  • Acrylic Aliphatic Polyurethane
  • Solid by Volume 40%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 40 micron over primer

  • Acrylic Aromatic Polyurethane
  • Solid by Volume 40%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 40 micron over primer
  • Recommended for Machine Tools, Power Electrical, Pump Motor Valves, Construction Infrastructure for indoor installation

  • Aromatic Polyurethane
  • Solid by Volume 40%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 40 micron over primer
  • Recommended as Topcoat for Pump, Motor, Valves applications & indoor installations

  • Acrylic Aliphatic Polyurethane
  • Solid by Volume 45%
  • Application by Roller, Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 50 micron over primer

  • Polyurethane based primer surfacer
  • Solid by Volume 40%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 -40 micron over primer

  • Polyurethane based MIO intermediate coat
  • Solid by Volume 50%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 60 -80 micron over primer

  • Two component Aliphatic Polyurethane based mastic coat
  • Solid by Volume 60%
  • Application by Brush, spray, HVLP or Airless gun
  • Recommended DFT 100 – 120 micron over well prepared surface like St 2, St 3 or blast cleaned

  • High build epoxy primer
  • Solid by Volume 70%
  • Application by Airless, Conventional and HVLP spray gun
  • Recommended DFT 70-100 micron in a Single coat over St2, St3 or Blast cleaned surface
  • Ideal for components exposed to wear and tear, abrasion like motors

  • Two component Acrylic PU primer
  • Solid by Volume 40%
  • Application by Brush, Conventional and HVLP spray gun
  • Recommended DFT 30 -40 micron over St2, St3 prepared surface
  • Recommended for genral industrial applications, Bus bodies, Auto component

  • Two-component PU Zinc Chromate primer
  • Solid by Volume 40%
  • Application by Brush, Conventional and HVLP spray gun
  • Recommended DFT 30 -40 micron over St2, St3, Seven tank Phosphated or Blast cleaned surface
  • Recommended for general industrial applications like electrical panels and alternators

  • Two-component PU Zinc phosphate primer
  • Solid by Volume 40%
  • Application by Brush, Conventional and HVLP spray gun
  • Recommended DFT 30 -40 micron over St2, St3, Seven tank Phosphated or Blast cleaned surface
  • Recommended for general industrial applications like Electrical panels, Alternators, Bus bodies, etc

  • Clear Polyurethane primer
  • Solid by Volume 40%
  • Application by Brush, Spray
  • Recommended DFT – 40 – 60 micron, over acid cleaned, abrasive cleaned concrete or emery scuffed Wood
  • Ideal primer for Wood, Concrete

  • Single pack quick drying topcoat
  • Solid by Volume 35%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 35 micron over primer

  • Single pack quick drying topcoat
  • Solid by Volume 35%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 35 micron over primer

  • Single pack quick drying topcoat
  • Solid by Volume 35%
  • Application by Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 35 micron over primer

  • Single pack air drying topcoat
  • Solid by Volume 35%
  • Application by Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 35 micron over primer

  • Single pack air drying topcoat
  • Solid by Volume 35%
  • Application by Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 35 micron over primer

  • Two component Aliphatic Polyurethane based In mold coating
  • Solid by Volume 20%
  • Application by spray
  • Recommended DFT 15 -18 micron

  • Single pack Vinyl topcoat
  • Solid by Volume 32%
  • Application by Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 50 micron over primer
  • Recommended for Project Process, Oil Gas, Infrastructure Construction

  • Single pack phenolic alky based topcoat
  • Solid by Volume 35%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 40 micron over primer
  • Confirms to the requirement of Transformer Oil resistance coating as per BIS 14947

  • Alkyd Melamine amino stoving topcoat
  • Solid by volume 35%
  • Application by Conventional spray, Electrostatic or HVLP spray
  • Recommended DFT 30 -40 micron
  • Recommended for Auto Component, Bus body

  • Single pack modified Vinyl based intermediate
  • Solid by Volume 32%
  • Application by Conventional, HVLP and Airless spray gun
  • Recommended DFT 65 – 85 micron over primer

  • Single pack Phenolic alkyd based MIO intermediate
  • Solid by Volume 40%
  • Application by Brush, Conventional, HVLP gun
  • Recommended DFT 30 – 40 micron over primer

  • Single Pack modified Vinyl based primer
  • Solid by Volume 32%
  • Application by Conventional, HVLP or Airless gun
  • Recommended DFT 65- 85 micron over St2, St3 or blast cleaned surface

  • Single Pack Phenolic alkyd based Oil resistance primer
  • Solid by Volume 40%
  • Application by brush, Conventional and HVLP spray gun
  • Recommended DFT 30 – 35 micron over St2, St3 or blast cleaned surface

  • Single Pack Air drying acrylate alkyd Primer
  • Solid by Volume 35%
  • Application by Conventional and HVLP spray gun
  • Recommended DFT 30 -35 microns over St2, St3 or Pretreated surface
  • Recommended for general industrial applications like steel furniture

  • Single Pack Air drying acrylate alkyd Primer
  • Solid by Volume 35%
  • Application by Conventional and HVLP spray gun
  • Recommended DFT 30 -35 microns over St2, St3 or Pretreated surface
  • Recommended for general industrial applications like steel furniture

  • Alkyd amino Stoving primer
  • Solid by Volume 35%
  • Application by Conventional, HVLP or Electrostatic spray gun
  • Recommended DFT 25 – 35 microns over St2, St3 or Pretreated surface
  • Recommended for general industrial applications like steel furniture

  • Single Pack Air drying Primer
  • Solid by Volume 35%
  • Application by Conventional and HVLP spray gun
  • Recommended DFT 30 -35 micron over St2, St3 pretreated surface
  • Recommended for general industrial applications

  • Single Pack Air drying primer cum rust convertor
  • Solid by Volume 35%
  • Application by Brush, Conventional and HVLP spray gun
  • Recommended DFT 30 -40 microns over St2, St3 or Pretreated surface
  • Recommended for Motors, Castings, Construction Infrastructure

  • Two Pack Polyurethane based primer cum rust convertor
  • Solid by Volume 40%
  • Application by Brush, Conventional and HVLP spray gun
  • Recommended DFT 30 -40 micron over St2, St3 or Pretreated surface

  • Single Pack Air drying primer cum rust convertor
  • Solid by Volume 35%
  • Application by Brush, Conventional and HVLP spray gun
  • Recommended DFT 30 -40 micron over St2, St3 or Pretreated surface

  • Elastomeric Polyurethane Coating for Coating for Metal and concrete
  • Solid by Volume 100%
  • Application by Dual component gun with static mixer arrangement
  • Recommended DFT – 1000 – 1200 micron, over a primer
  • Recommended for Cooling tower, Mounded bullets, External of MS Pipes.

  • Elastomeric Pure Polyurea Coating for Concrete, Metal, Expanded, Polystyrene
  • Solid by Volume 100%
  • Application by Dual component gun
  • Recommended DFT – 1000 – 1500 micron, over a primer
  • Recommended for Dams, Tunnels, Theme Parks, Drainage lines, Truck, Bed liner, Clarifiers, Water pipelines

  • Elastomeric Polyurethane coating for Concrete, Metal
  • Solid by Volume 100%
  • Application by Dual component gun
  • Recommended DFT – 1000 – 1500 micron, over a primer
  • Recommended for Mounded bullets, Tanks

  • Clear epoxy primer for concrete, metal, Wood
  • Solid by Volume 100%
  • Application by Brush, Spray
  • Recommended DFT – 40 – 60 microns, over acid, cleaned, abrasive cleaned
  • Concrete or emery scuffed Wood, blast cleaned Metal surface

  • Single pack Chlorinated rubber-based topcoat
  • Solid by Volume 35%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 -40 micron over primer

  • Single pack acid resistance topcoat
  • Solid by Volume 50%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 50 – 75 micron over primer

  • Chlorinated rubber based high build MIO Coating
  • Solid by Volume 40%
  • Application by Brush, Conventional, HVLP gun
  • Recommended DFT 50 -75 micron over primer
  • Recommended for Oil Gas, Infrastructure Construction

  • Single Pack modified Vinyl based primer
  • Solid by Volume 38%
  • Application by Brush, Conventional, HVLP gun
  • Recommended DFT 35 – 50 micron over St2, St3 or blast cleaned surface

  • Single Pack modified Chlorinated rubber based primer
  • Solid by Volume 35%
  • Application by Brush, Conventional, HVLP gun
  • Recommended DFT 35 – 50 micron over St2, St3 or blast cleaned surface

  • Single pack heat resistance paint
  • Solid by Volume 20%
  • Application by Conventional, HVLP spray gun
  • Recommended DFT 20 -30 microns on blast cleaned surface
  • Recommended for Pump Motor Valves, Project Process, Oil and Gas, Powe Electrical

  • Single pack Silicon-based heat resistance paint
  • Solid by Volume 25%
  • Application by Conventional, HVLP spray gun
  • Recommended DFT 15 -25 micron over blast cleaned surface or Zinc silicate primer
  • Recommended for Pump Motor Valves, Project Process, Oil and Gas, Powe Electrical

  • Single pack heat resistance paint
  • Solid by Volume 40%
  • Application by Conventional, HVLP spray gun
  • Recommended DFT 20 -30 micron over St2, St3 or blast cleaned surface

  • Alkyd Melamine amino stoving topcoat
  • Solid by volume 35%
  • Application by Conventional spray, Electrostatic or HVLP spray
  • Recommended DFT 30 -40 micron

  • Inorganic Ethyl Zinc Silicate based pre-fabrication Primer
  • Solid by Volume approx 30%
  • Application by Conventional, HVLP or Airless spray gun
  • Recommended DFT 25 -35 microns over blast cleaned surface

  • Inorganic Ethyl Zinc Silicate based Primer
  • Solid by Volume approx 55 – 62%
  • Application by Conventional, HVLP or Airless spray gun
  • Recommended DFT 60 – 75 micron over blast cleaned surface

  • Epoxy Novalac coating
  • Solid by Volume 67%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 100 – 125 micron over primer or blast cleaned surface

  • High build epoxy coating containing glass flake Finish Paint
  • Solid by Volume 88%
  • Application by Brush and Airless gun
  • Recommended DFT 150 – 200 micron over primer or blast cleaned surface

  • Solventless Epoxy Polyamine Finish Paint
  • Solid by Volume 100%
  • Application by Brush and Airless gun
  • Recommended DFT 250 – 500 micron over primer or blast cleaned surface

  • Solventless Epoxy Cycloaliphatic amine/ Polyamine Finish Paint
  • Solid by Volume 100%
  • Application by Brush and Airless gun
  • Recommended DFT 100 – 150 micron over primer

  • Solventless Epoxy Polyamide Finish Paint
  • Solid by Volume 100%
  • Application by Brush and Airless gun
  • Recommended DFT 100 – 150 micron over primer

  • Epoxy Coal tar high build Finish Paint
  • Solid by Volume 70%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 75 -100 micron over primer or blast cleaned surface

  • Epoxy Polyamide Finish Paint
  • Solid by Volume 40%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 30 – 40 micron over primer

  • Epoxy Polyamide Finish Paint
  • Solid by Volume 58%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 65 – 75 micron over primer

  • Solventless Epoxy Novalac coating
  • Solid by Volume 100%
  • Application by Brush, Airelss and Dual component gun
  • Recommended DFT 300 – 500 micron over primer or blast cleaned surface

  • Epoxy Polyamide Finish Paint
  • Solid by Volume 58%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 65 – 75 micron over primer

  • Epoxy Polyamine intermediate cum finish coat
  • Solid by Volume 65%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 75 – 100 micron over primer

  • Epoxy MIO intermediate
  • Solid by Volume 50%
  • Application by Brush, Conventional, HVLP and Airless gun
  • Recommended DFT 60 – 80 micron over primer

  • Single component modified Epoxy primer
  • Solid by Volume 40%
  • Application by Brush, Dipping Conventional and HVLP spray gun
  • Recommended DFT 30 -50 micron over St2, St3 or Blast cleaned surface

  • Surface tolerant mastic high build epoxy primer
  • Solid by Volume 80%
  • Application by Airless, Conventional and HVLP spray gun
  • Recommended DFT 80-100 micron in a Single coat over Minimal prepared or blast cleaned surface.
  • Recommended for tanks, structures, chemical plants, Power segment equipments, motors

  • Surface tolerant Coal Tar epoxy primer cum finish coat
  • Solid by Volume 63%
  • Application by Airless, Conventional, brush and HVLP spray gun
  • Recommended DFT 100 -120 micron
  • Excellent water resistance, hence recommended for water storage tanks

  • Surface tolerant mastic high build epoxy primer
  • Solid by Volume 80%
  • Application by Airless, Conventional and HVLP spray gun
  • Recommended DFT 75 -100 micron in a Single coat over Minimal prepared or blast cleaned surface.
  • Recommended for tanks, structures, chemical plants, Power segment equipments, motors

  • Surface tolerant high build epoxy primer.
  • Solid by Volume 63%
  • Application by Airless, Conventional and HVLP spray gun
  • Recommended DFT 60 – 80 micron over St 2, St3 or blast cleaned surface
  • Recommended for tanks, structures, chemical plants, Power segment equipments, motors

  • Epoxy Zinc phosphate primer Grey
  • Solid by Volume 40%
  • Application by Conventional, HVLP, Flow coat and Airless application
  • Recommended DFT 30 -40 micron over St 2, St3 or blast cleaned surface
  • Recommended for general industrial applications like Electrical panels, Construction equipment, Radiators, etc.

  • Epoxy Zinc chromate primer Yellow
  • Solid by Volume 40%
  • Application by Conventional Brush,Spray, HVLP, Airless gun, Roller or Flow coating
  • Recommended DFT 30 -40 micron over St 2, St3 or blast cleaned surface
  • Recommended for Pumps, Motor and Valve

  • Epoxy Redoxide Zinc chromate primer
  • Solid by Volume 40%
  • Application by Conventional Brush, Spray, HVLP, Airless gun, Roller or Flow coating
  • Recommended DFT 30 -40 micron over St 2, St3 or blast cleaned surface
  • Recommended for moderate to mild chemical environment

  • Two component Epoxy Redoxide Zinc phosphate primer.
  • Solid by Volume 40 %
  • Application by Conventional Brush,Spray, HVLP, Airless gun, Roller or Flow coating
  • Recommended for Plants, general industrial application
  • Recommended DFT 30 -40 micron over St 2, St3 or blast cleaned surface

  • Clear epoxy penetrating primer for concrete, Wood
  • Solid by Volume 50%
  • Application by Brush, Spray
  • Recommended DFT – 40 – 60 micron, over acid cleaned, abrasive cleaned concrete or emery scuffed Wood
  • Ideal primer for Wood, Concrete.

  • Epoxy high build primer
  • Solid by Volume 63 %
  • Application by Airless, Conventional and HVLP spray gun
  • Recommended DFT 70 -80 micron over blast cleaned surface
  • Ideal for tanks, structures, chemical plants, Power segment equipments, motors

  • Epoxy pre fabrication primer
  • Solid by Volume 30 %
  • Application by Conventional, HVLP and Airless gun
  • Recommended DFT 20 -25 micron over blast cleaned surface
  • Recommended for engineering building, Project, Sheet metal protection

  • Epoxy Zinc phosphate Primer
  • Solid by Volume 48 %
  • Application by Conventional, HVLP, Flow coat, Flood coat, and Airless gun
  • Recommended DFT 30 -50 micron, surface preparation – Seven tank phosphating, Blasting, Manual cleaning
  • Recommended for Tractors, Construction equipments, general industrial applications